Welcome
See Also
Product Categories
Contact Us
Captcha Code
 

Thyristor - CD3000E 3PH 25A to 500A DC Linear, SC/BF/PA, CL, FB

 

330V to 600VAC Supply, DC Logic, 4-20mA, 0-10V DC linear, 10K potentiometer or RS485 Comms input.

 

Designed to drive resistive or transformer loads with delta or star connection. A selection of zero cross, burst, single cycle or phase angle firing available. Includes Power, Current or Voltage feedback. Configurable via RS485 communications (Modbus protocol) for all inputs, firing & performance parameters.
Configuration software available as a download at no extra cost

 

Please register to access our files.

Once registered, you will be redirected to this page, and you won't have to register again to access files on this site.

We promise never to share your information with anyone! See our Privacy Policy

Name:
Surname:
Email:
Company:
 
  • Three leg switching of 3/4 wire star or 3/6 wire delta loads
  • Fully digital and user configurable for all inputs, firing modes, feedback modes and load types
  • Firing modes include zero crossing (ZC), burst firing (BF), single cycle (SC), soft start + burst firing (S+BF) and phase angle + soft start (S+PA)
  • Microprocessor based electronic circuit fully isolated from power
  • Universal input signal with automatic zero/span calibration
  • Power feedback or voltage compensation
  • RS485 Comms MODBUS protocol as standardUnbalanced loadHeater break alarm to diagnose partial or total load failure and short circuit
  • Control & monitor (power, current & voltage) via external keypad (CD-KP)
  • IP20 Protection
 

Please register to access our files.

Once registered, you will be redirected to this page, and you won't have to register again to access files on this site.

We promise never to share your information with anyone! See our Privacy Policy

Name:
Surname:
Email:
Company:
 
Voltage Power Supply
Range 330V to 480V, 600V on request
 
 
 
Firing Mode
One of these firing modes can be configured Burst Firing (BF), Single Cycle (SC), Soft Start + Burst Firing (S+BF), Soft Start + Phase Angle (S+PA) and Delayed Triggering (DT)
 
Auxiliary Voltage Supply
90-265V; 20VA power consumption. Fan voltage supply: 230V ±15% as a standard and 110V on request.
 
Heater Break Alarm
Circuit microprocessor based to diagnose partial or total load failure and short circuit on Thyristors
 
Mounting
Panel mounting
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Please register to access our files.

Once registered, you will be redirected to this page, and you won't have to register again to access files on this site.

We promise never to share your information with anyone! See our Privacy Policy

Name:
Surname:
Email:
Company:
 
 

Please register to access our files.

Once registered, you will be redirected to this page, and you won't have to register again to access files on this site.

We promise never to share your information with anyone! See our Privacy Policy

Name:
Surname:
Email:
Company:
 
 
 
 
 
 
 
 
 
 
 
 

Please register to access our files.

Once registered, you will be redirected to this page, and you won't have to register again to access files on this site.

We promise never to share your information with anyone! See our Privacy Policy

Name:
Surname:
Email:
Company: